TY - JOUR
T1 - Fabrication of ultra-sharp tips from carbon fiber for scanning tunneling microscopy investigations of epitaxial graphene on 6H-SiC(0 0 0 1) surface
AU - Morán Meza, J. A.
AU - Lubin, C.
AU - Thoyer, F.
AU - Villegas Rosales, K. A.
AU - Gutarra Espinoza, A. A.
AU - Martin, F.
AU - Cousty, J.
N1 - Publisher Copyright:
© 2015 Elsevier Ltd. All rights reserved.
PY - 2015/5/1
Y1 - 2015/5/1
N2 - Abstract The fabrication of ultra-sharp tips from carbon fiber (CF), which are mounted on a qPlus probe for combined dynamic scanning tunneling microscopy (STM) and frequency modulation atomic force microscopy (FM-AFM) experiments, is reported. The carbon fiber tips were electrochemically etched in a KOH or NaOH solution, using different electronic devices. CF tips with an apex radius ∼10 nm, as deduced from the measured slopes of the Fowler-Nordheim plots (kR < 70 nm for k ∼ 6), were routinely obtained with a homemade electronic device that controls the intensity of the etching current. Then, these conductive CF tips were also characterized by imaging the 6H-SiC(0 0 0 1) surface covered by an epitaxial graphene layer in ultra-high vacuum (UHV). The lattice of the (63×63) R30 reconstruction was regularly imaged by STM working either in non-oscillating mode or in dynamic mode, which also maps the variations of the force gradient. From these measurements with a constant mean-tunneling-current of 20 pA, it was found that the STM tip suffered variations of the tip/surface force gradient in between 8.25 and 16.50 N/m when it scanned the epitaxial graphene layer on the reconstructed 6H-SiC(0 0 0 1) surface.
AB - Abstract The fabrication of ultra-sharp tips from carbon fiber (CF), which are mounted on a qPlus probe for combined dynamic scanning tunneling microscopy (STM) and frequency modulation atomic force microscopy (FM-AFM) experiments, is reported. The carbon fiber tips were electrochemically etched in a KOH or NaOH solution, using different electronic devices. CF tips with an apex radius ∼10 nm, as deduced from the measured slopes of the Fowler-Nordheim plots (kR < 70 nm for k ∼ 6), were routinely obtained with a homemade electronic device that controls the intensity of the etching current. Then, these conductive CF tips were also characterized by imaging the 6H-SiC(0 0 0 1) surface covered by an epitaxial graphene layer in ultra-high vacuum (UHV). The lattice of the (63×63) R30 reconstruction was regularly imaged by STM working either in non-oscillating mode or in dynamic mode, which also maps the variations of the force gradient. From these measurements with a constant mean-tunneling-current of 20 pA, it was found that the STM tip suffered variations of the tip/surface force gradient in between 8.25 and 16.50 N/m when it scanned the epitaxial graphene layer on the reconstructed 6H-SiC(0 0 0 1) surface.
UR - http://www.scopus.com/inward/record.url?scp=84924565690&partnerID=8YFLogxK
U2 - 10.1016/j.carbon.2015.01.050
DO - 10.1016/j.carbon.2015.01.050
M3 - Artículo (Contribución a Revista)
AN - SCOPUS:84924565690
SN - 0008-6223
VL - 86
SP - 363
EP - 370
JO - Carbon
JF - Carbon
M1 - 9674
ER -